Occupational Asthma Reference

Carbone U, Montuori P, Novi C, Triassi M, Respiratory function in power plant workers exposed to nitrogen dioxide, Occup Med, 2014;64:644-646,10.1093/occmed/kqu129

Keywords: Nitogen oxides, NOX, nitrogen dioxide, Italy, spirometry, cross-section, exposure, electricity generation, power station

Known Authors

If you would like to become a known author and have your picture displayed along with your papers then please get in touch from the contact page. Known authors can choose to receive emails when their papers receive comments.

Abstract

Background
Power plant workers are potentially exposed to nitrogen dioxide (NO2) and may therefore be at higher risk of pulmonary diseases than the general population.

Aims
To assess the association of NO2 exposure with spirometric abnormalities in power plant workers.

Methods
Forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC) and forced expiratory ratio (FER = FEV1/FVC) were correlated with demographic characteristics, smoking history and environmental exposure to NO2 in power plant workers exposed to environmental NO2 at work and in a control group of administrative employees. Twenty-four hour environmental NO2 concentrations were measured at each workplace.

Results
The concentrations of environmental NO2 ranged from 1.21 to 7.82mg m-3 with a mean value of 3.91 + 1.51mg m-3. The results showed that FEV1 and FVC were significantly lower in 347 power plant workers than in the 349 controls (P < 0.001). The FER was significantly correlated with age, environmental NO2 concentration, smoking and height.

Conclusions
Occupational exposure to NO2 emissions in power plants is significantly associated with lung function abnormalities as assessed by spirometry. Spirometric measurements in power plant workers exposed to NO2 emissions may be an effective means of detecting early signs of impaired respiratory health in this group of workers.