Occupational Asthma Reference

Baldwin DR, Gannon PFG, Bright P, Newton DT, Robertson AS, Venables KM, Graneek B, Barker RD, Cartier A, Malo JL, Wilsher M, Pantin CFA, Burge PS, Interpretation Of Occupational Peak Flow Records: Level Agreement Between Expert Clinicians And OASYS-2, Thorax, 2002;57:860-864,

Keywords:

Known Authors

David Baldwin, Nottingham, UK David Baldwin

André Cartier, Hôpital de Sacré Coeur, Montreal, Quebec, Canada André Cartier

Sherwood Burge, Oasys Sherwood Burge

Charles Pantin, Keele, UK Charles Pantin

Paul Gannon, Dupont Paul Gannon

Phil Bright, Oasys Phil Bright

Darren Newton, Oasys Darren Newton

Alastair Robertson, Selly Oak Hospital Alastair Robertson

Jack Barker, Kings College Hospital, London Jack Barker

Kate Venables, Oxford University Kate Venables

Jean-Luc Malo, Hôpital de Sacré Coeur, Montreal, Quebec, Canada Jean-Luc Malo

If you would like to become a known author and have your picture displayed along with your papers then please get in touch from the contact page. Known authors can choose to receive emails when their papers receive comments.

Abstract

Background
Oasys-2 is a validated diagnostic aid for occupational asthma that interprets peak expiratory flow (PEF) records as well as generating summary plots. The system removes inconsistency in interpretation, which is important if there is limited agreement between experts. A study was undertaken to assess the level of agreement between expert clinicians interpreting serial PEF measurements in relation to work exposure and to compare the responses given by Oasys-2.
Method
35 PEF records from workers under investigation for suspected occupational asthma were available for review. Records included details of nature of work, intercurrent illness, drug therapy, predicted PEF, rest periods, and holidays. Simple plots of PEF and the Oasys-2 generated plots were available. Experts were advised that approximately 1 hour was available to review the records. They were asked to score each work-rest-work (WRW) period and each rest-work-rest (RWR) period for evidence of occupational effect. At the end of each record scores of 0-"100%" were given for evidence of "asthma" and "occupational effect" for the whole record. Kappa values were calculated for each scored period and for the opinions on the whole record. The scores were converted into four groups (0-25%, 26-50%, 51-75%, 76-"100%") and two groups (0-50% and 51-"100%") for analysis. This is relevant to scores produced by Oasys-2. Agreement between Oasys-2 scores and each expert was calculated.
Results
24 of 35 records were analysed by seven experts in the allotted time. For whole record occupational effect, median kappa values were 0.83 (range 0.56-0.94) for two groups and 0.62 (0.11-0.83) for four groups. For asthma, median kappa values were 0.58 (0-0.67) and 0.42 (0.15-0.70) for two and four groups respectively. For all WRW and RWR periods kappa values were 0.84 (0.42-0.94) and 0.70 (0.46-0.87) respectively. Agreement between Oasys-2 and individual experts showed a median kappa value of 0.75 (0.50-0.92) for two groups and 0.50 (0.39-0.70) for four groups. Kappa values for the median expert score v Oasys-2 were 0.75 for two groups and 0.67 for four groups. Agreement was poor for records with intermediate probability, as defined by Oasys-2.
Conclusion
Considerable variation in agreement was seen in expert interpretation of occupational PEF records which may lead to inconsistencies in diagnosis of occupational asthma. There is a need for an objective scoring system which removes human variability, such as that provided by Oasys-2.