Occupational Asthma Reference

Meza F, Chen C, Hudson N, Investigation of Respiratory and Dermal Symptoms Associated with Metal Working Fluids at an Aircraft Engine Manufacturing Facility, Am J Industr Med, 2013;56:1394-1401,10.1002/ajim.22253

Keywords: air measurrement, USA, metal-working fluid, endotoxin, occupational asthma, dermatitis,

Known Authors

If you would like to become a known author and have your picture displayed along with your papers then please get in touch from the contact page. Known authors can choose to receive emails when their papers receive comments.

Abstract

Background
Each year, 1.2 million metalworkers are exposed to metalworking fluids (MWFs), which can cause dermal and respiratory disease. The National Institute for Occupational Safety and Health (NIOSH) conducted a health hazard evaluation of MWF exposures at an aircraft engine manufacturing facility. The objectives were to determine employee exposures to endotoxin and MWFs in the air, characterize symptoms experienced by employees working with MWFs, compare them to symptoms of employees unexposed to MWFs, and make recommendations for reducing exposures based on results.

Methods
407 workers were categorized as MWF exposed or MWF unexposed and completed questionnaires. Estimated prevalence ratios (PR) of dermatitis, asthma, and work-related asthma (WRA) symptoms were calculated. Airborne concentrations of MWF and endotoxin were measured, and work practices observed.

Results
MWF exposed workers had a significantly higher prevalence of dermatitis on wrists/forearms (PR 2.59; 95% CI 1.22, 5.46), asthma symptoms (PR 1.49; 95% CI 1.05, 2.13) and WRA symptoms (PR 2.10; 95% CI 1.22, 3.30) than unexposed workers. Airborne concentrations of MWF were below the NIOSH recommended exposure limit (REL) for MWF aerosols (thoracic particulate mass).

Conclusions
Despite MWF exposures below the NIOSH REL, exposed workers had a higher prevalence of asthma, WRA, and dermatitis symptoms than unexposed workers. Recommendations to reduce exposure included configuring mist collectors to automatically turn on when the machine is in use, and enforcing enclosure use.

Full Text

Comments

Please sign in or register to add your thoughts.


Oasys and occupational asthma smoke logo